Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Military Medical Sciences ; (12): 814-817,826, 2013.
Article in Chinese | WPRIM | ID: wpr-598607

ABSTRACT

Objective To calculate the electric field intensity and transmembrane voltage of spherical cells and ellipsoi -dal red blood cells ( RBC) in an extremely low frequency electromagnetic field .Through this calculation , we can provide reference to the search for interaction targets and mechanics between the extremely low frequency electromagnetic field and organisms.Methods The Finite Element Method was used in the numerical computation for the spherical cell model and the ellipsoidal RBC model .Results The electric field intensity of the two types of cells on the cellular membrane was both significantly higher than the applied electric field strength , and the values of the induced field strength and transmembrane voltage varied with the direction of the electric field periodically .Conclusion The cell shape and direction of the applied electric field are not the main determinants of the cellular membrane electric field intensity and the transmembrane voltage compared with electromagnetic parameters .The distribution of the electric field intensity and transmembrane voltage are re-lated to the direction of the applied electric field.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 432-434,448, 2009.
Article in Chinese | WPRIM | ID: wpr-597290

ABSTRACT

Objective To establish an efficiency calibration method without a radioactive source for Inspector 2000 gamma spectroscopy system.Methods At the fwst step,geometry parameters of the detector were properly specified by comparisons of FEPE(Full Energy Peak Efficiency)between Monte Carlo(MC)calculations and the average measured values of HPGe and NaI detectors using point sources(137 Cs).The differences between calculations and measurements were generally within ±10% for gamma rays.Then,Monte Carlo simulation was used to evaluate the counting efficiency of Nal(TI)and HPGe detectors for BOMAB phantoms.Corresponding efficiency curves and functions were fitted.Results The counting efficiency received from the fitted efficiency functions had a good agreement with those from MC simulation.The bias for Nal detector ranged from-19% to 18%,while the bias for HPGe detector ranged from-11% to 17%.The above errors were totally acceptable in the on-site deployment during nuclear and radiological emergency events.Conclusions Monte Carlo method is simple,time and laborsaving in determing the counting efficiency of gamma spectroscopy system.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 301-303, 2008.
Article in Chinese | WPRIM | ID: wpr-400463

ABSTRACT

Objective To find out the relationship between the weight and whole body averaged SAR. and the relationship between the weight and the EM energy absorption in rat model exposed to 3 GHz microwave irradiation.Methods Based on 3D rat NMR images,a rat EM model consisting of 45 tissues was established, then by changing the size of model cell,16 models of which the sizes varied from 9 cm to 24 cm, and the weights from 16 g tO 334 g correspondingly were established too.Using FDTD method,the induced electric fields in these rat models were calculated,and then SAR and EM energy absorption have been obtained accordingly.Results The relationship between the weight and the whole body averaged SAR of rat model exposed to 3 GHz microwave irradiation can be divided into three sections,and each of them can be fitted into one line.In small rat section, SAR changed sharply;in middle rat section,SAR changed moderately;in large rat section,SAR changed litflely.The relationship between the weight and the EM energy absorption of rat model were fitted into one quadratic polynomial curve.The EM energy absorption was almost identical when the model is small,with the increasing of the weight,the EM energy absorption also increases,but the increasing ratio of the energy is less than that of the weight.Conclusions Larger rat absorbs more EM energy,but gets less SAR.Exposed to the same irradiation,the dose differences of larger rat is much less than that of smaller rat because of the changes in body weight,so the larger rat is to be recommended.

4.
Journal of Chongqing Medical University ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-574225

ABSTRACT

0.05).Conclusion:Infiltrating throuth the wall of bile duct and into biliary lumen is the pathologic foundation for extrabiliary malignant tumor inducing bile duct stenosis.

5.
Chinese Journal of General Surgery ; (12)1994.
Article in Chinese | WPRIM | ID: wpr-673722

ABSTRACT

Objective To demonstrate the incidence and relative factors of hypothyroidism after partial thyroidectomy (PTC). Methods The records of all euthyroidsm patients who underwent hemithyroidectomy from 1988 to 2000 were reviewed to determine the incidence of postoperative hypothyroidism and the predisposing factors. All the patients age, gender, serum TSH TGA and TPO levels,and the weight of resected thyroid tissue were evaluated. Hypothyroidsm patients were evaluated for the symptoms , timing of diagnosis , and thyroxine therapy. Results Hypothyroidism was diagnosed in 41(3.4%) of 1 210 patients ,inclnding subclinical hypothyroidsm in 28 and overt in 13.The mean postoperative serum TSH level was (9.22?3.36)mU/L. The mean preoperative serum TSH level was (3.14?1.05)mU/L in hypothyroidsm patients but in euthyroid patients was (1.07?0.72)mU/L(P

SELECTION OF CITATIONS
SEARCH DETAIL